P.O Box 890 Cary,NC 271513
0015027181948

Refrigeration & Air Conditioning Training System

Refrigeration & Air Conditioning Training System

I. Product Overview

The SR2011 training system is designed to demonstrate the fundamentals of refrigeration and air conditioning. It provides a practical and interactive platform for students to learn system components, operation principles, and fault diagnostics.

When combined with the base refrigeration and air conditioning models, the SR2011 offers comprehensive experimental training on:

Basics of the refrigeration cycle

Principles of air conditioning

Components of refrigeration and AC systems

System operation & troubleshooting techniques

________________________________________

II. Learning Objectives / Experiments

1. Fundamentals of the refrigeration cycle

2. Fundamentals of air conditioning

3. Identification of refrigeration & air conditioning components

4. System operation demonstration

5. Fault finding and troubleshooting in refrigeration systems

________________________________________

III. Specifications

1. Basic Experiments – Study refrigeration & air conditioning by combining the base unit with models

2. HSI Technology – Modern training system with high system integration

3. Condensing Unit – Includes compressor, condenser, and receiver

4. Refrigerant Hoses – Quick connections between condensing unit and models

5. Secure Mounting – Models attached firmly with fasteners

6. Manometer with Temperature Scale – For monitoring refrigerant pressure and temperature

7. Eco-Friendly Refrigerant – R134a, CFC-free

8. System Control – Managed via solenoid valves and educational software

9. Software Functions – Data acquisition, system control, experiment guidance

________________________________________

IV. Technical Data

Condensing Unit Capacity: 340 W at 0/32°C

Measuring Ranges:

o Temperature:

1×: -50 … 50°C

3×: 0 … 100°C

o Pressure:

Intake side: -1 … 9 bar

Delivery side: 2× -1 … 15 bar

________________________________________

V. Dimensions & Weight

Dimensions (L × W × H): 830 × 650 × 320 mm

Weight: ~60 kg

________________________________________

VI. Requirements for Operation

Electrical Supply:

o 230 V, 50/60 Hz, 1 phase

o or 120 V, 60 Hz/CSA, 1 phase